D297 12 V Projected Beam Smoke Detector

D297 12 V Projected Beam Smoke Detector

D297 12 V Projected Beam Smoke Detector

The D297 Projected Beam Smoke Detector is used in clear open structures such as arenas, atriums, auditoriums, ballrooms, churches, factories, museums, and warehouses. Each D297 detector consists of a transmitter, a receiver, and a remote annunciation plate. Because the transmitter and receiver typically mount on the ceiling or high on walls or columns, they provide an effective and unobtrusive means of supervising public areas for fire protection. The D306 Remote Indicator Plate, included with the D297, provides a convenient means of verifying detector status. Install it anywhere within 500 ft (152 m) of the beam receiver (when using 18 AWG [1.2 mm] wire). The D306 has three LEDs to indicate normal, trouble, and alarm conditions, and test points to monitor the detector circuit.

Functions Alarm Operation The transmitter emits a pulsed infrared beam. The receiver measures the intensity of the beam over a period of time and compares this data with an alarm threshold. Select one of six levels of sensitivity for the alarm threshold through a switch on the receiver. If the receiver senses a signal strength below the preset alarm threshold in excess of the alarm period it signals an alarm.

Signal Loss Compensation The receiver automatically compensates for the gradual loss of signal due to dust and dirt build-up on the cover. The receiver measures the intensity of the pulsed infrared beam emitted by the transmitter over a period of time and compares this data with a preset trouble threshold. When 50% of the signal is lost, the receiver sends a trouble signal to the control panel. When the dust and dirt build-up is cleaned or the blockage is removed, the detector automatically resets.

Tamper Detection If the covers to the transmitter or receiver are removed, the detector sends a trouble signal to the control panel.

Trouble Detection The receiver measures the intensity of the pulsed infrared beam emitted by the transmitter over a period of time and compares this data with a preset trouble threshold. When 90% or more of the signal is lost for more than 20 seconds, as might happen if an object blocked the beam, the receiver sends a trouble signal to the control panel.

Sản phẩm liên quan

UPS 2416 A Universal Power Supply

The UPS Power Supply Unit is a plug-and-play power supply for the entire power supply to the control panel. UPS

Panel Controller

Interconnection of up to 32 Panel Controllers,
Remote Keypads and OPC server

FNS-320 Beacons Conventional

Compact, robust and maintenance-free
Reliable, bright light, and long-lived with Xenon flash

FNM-320 Sounders Conventional

Volume up to 112 dB(A)
Compact, robust and maintenance-free

FMC‑210‑DM Double Action Call Points

Adjustment of the Manual Call Point after alarm triggering

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors

High reliability of detection thanks to evaluation electronics
Active adjustment of the thresho

D297 12 V Projected Beam Smoke Detector

Operates over distances between 30 ft (9 m) and
350 ft (107 m)

BCM‑0000‑B Battery Controller Module

The BCM-0000-B Battery Controller Module monitors the power supply of the entire control panel. It controls the charging of up to four batteries (12 V/24 Ah to 12 V/26 Ah or 12 V/36 Ah to 12 V/45 Ah). The charging is actuated by temperature and time.